PATTON ELECTRONICS CO.

3012-14-18/V24

INSTALLATION AND OPERATIONS MANUAL

137001UA

Caution, Disconnect the POWER Before Removing The Cover. Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.

CHAPTER 2 - SETUP AND INSTALLATION

Power Connection

Before connecting the MSD to an AC power source the top cover must be installed and secured with the supplied screws. The unit is supplied with a 110/220V voltage switch. Turn the switch with a coin or

screw driver to the appropriate voltage

110 / 220VA Switch

 

for your country. EXAMPLE: United

Fuse Drawer

States of America, set to 110V. The

 

unit is supplied with an IEC power

110

connector next to the voltage select

220

 

switch. Plug the power cord into the

 

connector until it is firmly seated. You

 

may now connect the power cord

 

into your AC outlet.

IEC Power Connector

Factory Configuration Switch Settings

The MSDs are configured prior to shipment with the switches set to the following default positions:

3012/V24 (CTS MSD-2C)

Switch 3 - positions 4, 5 and 6 to OFF, 1, 2 and 3 to ON

Anti-Stream = 40sec. and Disabled

CTS Delay = No Delay

Signal Ground not connected to Chassis Ground

JP4 and JP5 to IN

Provide Pin 9 and 10 Test Voltage

JP1, JP2, and JP3 to IN

Factory Testing Straps Must be installed

3014/V24 (CTS MSD-4C)

Switch 5 - positions 4 and 6 to OFF, 1, 2, 3 and 5 to ON

Anti-Stream = 40sec. and Disabled

Switching Mode = Priority

Signal Ground not connected to Chassis Ground

2-1

Setup & Installation

Page 8
Image 8
Patton electronic 3012/V24, 3014/V24, 3018/V24 manual 3012/V24 CTS MSD-2C