PATTON ELECTRONICS CO. 3012-14-18/V24 INSTALLATION AND OPERATIONS MANUAL

137001UA

JP4 and JP5 to IN

Provided Pin 9 and 10 Test Voltage

JP6 to OUT

CTS delay = No Delay

JP1, JP2 and JP3 to IN

Factory Test Jumpers must be installed

3018/V24 (CTS MSD-8C)

Switch 9 - positions 4 and 6 to OFF, 1, 2, 3 and 5 to ON

Anti-Stream = 40sec. and Disabled

Switching Mode = Priority

Signal Ground not connected to Chassis Ground

JP4 and JP5 to IN

Provided Pin 9 and 10 Test Voltage

JP6 to OUT

CTS delay = No Delay

JP1, JP2 and JP3 to IN

Factory Test Jumpers must be installed

If the system application requires one or more of the default settings to be changed, it will be necessary to remove the top cover of the enclosure to access and change the DIP switches located on the printed circuit board.

Disassembly

Remove the top cover by unscrewing the phillips head screws located on the left and right sides of the unit. The configuration switches and jumpers are located on the PCB as indicated on the appropriate strapping guide in the Appendix of this manual. After the switch selection activity is completed, REINSTALL THE TOP COVER BEFORE

CONNECTING TO AN AC POWER SOURCE.

Setup & Installation

2-2

Page 9
Image 9
Patton electronic 3012/V24, 3014/V24, 3018/V24 manual 3018/V24 CTS MSD-8C