Installation to Solid Concrete or Cinder Block
WARNING
•When installing Peerless wall mounts on cinder block, verify that you have a minimum of
•Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
1 | Make sure that wall plate (A) is level, use it as a |
template to mark two mounting holes. Drill two 1/4" |
(6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (H) in holes flush with wall as shown (right). Place wall plate over anchors and secure with two #14 x 2.5" screws (G). Level, then tighten all fasteners.
Skip to step 2 on page 6 for VESA 200 mm and 200 mm x 200 mm patterns.
Skip to step 2 on page 7 for VESA 75 mm and 100 mm patterns.
WARNING
•Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• | Always attach concrete expansion anchors directly to |
| |
• | Never attach concrete expansion anchors to concrete |
1 | concrete |
| |
| surface |
|
|
H
Drill holes and insert anchors (H).
2 | A |
|
G H
Place plate (A) over anchors (H) and secure with screws (G).
3
Tighten all fasteners.
covered with plaster, drywall, or other finishing mate- |
rial. If mounting to concrete surfaces covered with a |
finishing surface is unavoidable, the finishing surface |
must be counterbored as shown below. Be sure |
concrete anchors do not pull away from concrete |
when tightening screws. If plaster/drywall is thicker |
than 5/8", custom fasteners must be supplied by |
installer. |
A
SOLID |
|
|
CONCRETE | CINDER |
|
| BLOCK | |
|
|
H
|
| INCORRECT |
| CORRECT |
|
VIEW | wall | concrete | wall plate | concrete | G |
CUTAWAY | plate |
|
|
| |
| plaster/ |
| plaster/ |
| |
|
|
|
| ||
|
| dry wall |
| dry wall |
|
|
|
|
| 5 of 8 | ISSUED: |