Pelco BB5L operation manual Interconnect Circuit Board for Spectra Lite, From controller

Models: BB5L

1 20
Download 20 pages 39.63 Kb
Page 14
Image 14
Figure 11. Interconnect Circuit Board for Spectra™ Lite

 

 

CONNECTOR

HTR/FAN

VIDEO

FOR OPTIONAL

TRANSLATOR

 

RS-422

SUBASSEMBLY

CONTROL

 

SIGNALS

 

PWR IN

RX–

RX+

TX–

TX+

FUSE

24 VAC

MIDDLE

PIN IS

GND

DOME DRIVE CONNECTOR

FAN

NOTE: Connect only a low volt- age device to the relay output. Maximum current rating of the re- lay contacts is two amperes.

CAUTION: The maxi- mum output of AUX 2 is 150 mA. If you connect a device that draws more current, you could destroy the output transistor. The output is intended to drive logic circuits or low-current devices. If higher current is required, connect the output to a relay.

CAUTION: Leave ad- equate slack in the wiring to permit the door to open without pulling on the con- nectors.

POWER

 

(24 VAC ONLY)

1.6 A

Figure 11. Interconnect Circuit Board for Spectra™ Lite

4.Control - If you are using a Coaxitron® controller, control signals will be trans- mitted over the video coax.

If you are using RS-422 (P or D) control signals, connect the control lines from the controller to the circuit board. Connect the wires as follows:

From controller

To 4-Wire terminal on circuit board

RX-

TX-

RX+

TX+

TX-

RX-

TX+

RX+

 

 

5.Heater/Fan - The heater/fan is not used on indoor models.

6.

Alarm Inputs - (Spectra™ [Version 3.0] and Spectra II™ Only) If you need

 

alarm inputs, connect them. The maximum number of alarm inputs is seven.

 

Refer to Figure 6 for a typical wiring example. Alarm inputs require a ground

 

signal through a contact closure, such as a switch.

7.

AUX 1 - (Spectra™ [Version 3.0] and Spectra II™ Only) An AUX 1 com-

 

mand from the controller will activate the relay output. If you need the relay, wire

 

it as required. Refer to Figure 6. The relay contacts are shown when AUX 1 is

 

inactive. When an AUX 1 command is issued, the relay contacts will reverse and

 

remain latched until a clear command is issued.

8.

AUX 2 - (Spectra™ [Version 3.0] and Spectra II™ Only) An AUX 2 command

 

from the controller will place a ground at the output of AUX 2 to operate the device

 

connected to it. The output will remain latched until a clear command is issued. If

you need the AUX 2 output, wire it as required. Refer to Figure 6 for typical wiring examples.The AUX 2 output is an open collector transistor driver which is capable of passing a maximum of 150 mA at 32 VDC. It is capable of driving TTL logic circuits or low-current reed relays. If you use an external relay, make sure that both the supply voltage and the current requirements are well below the maximum of 32 VDC and 150 mA. Exceeding these values will cause permanent damage to the dome. If you are not familiar with open collector drive requirements, contact Pelco technical support for assistance.

9.Close the door and tighten the thumbscrew securely.

10.Turn on power to the back box. The red LED on the interconnect door should light. The fan will not operate until a dome drive is installed.

If the LED does not light, correct the trouble before proceeding. Refer to Sec- tion 5.0, TROUBLESHOOTING.

14

Pelco Manual C1488M-A (9/98)

Page 14
Image 14
Pelco BB5L Interconnect Circuit Board for Spectra Lite, From controller, To 4-Wire terminal on circuit board