Pelco C10DN manual Connecting Dc Power, Warnings

Models: C10DN

1 32
Download 32 pages 52.14 Kb
Page 13
Image 13
CONNECTING DC POWER

CONNECTING DC POWER

The C10DN Series camera requires a power supply of 12 VDC ±15% 10.2–13.8 VDC. Make sure the power supply has a minimum rating of 390 mA.

Manual backgroundWARNINGS:

For safety, include a 1.0 A slow blow fuse when connecting DC power, as shown in Figure 5.

The DC power supply must be UL and CE certified.

Make sure you wire the power polarity correctly.

To connect DC power refer to Figure 5, and then complete the following steps:

1.Strip at least 0.4 inches (10 mm) of the insulation from both power wires.

2.Connect the negative wire from the power supply to the indicated hole in the terminal block that is supplied with the camera.

3.Connect the positive wire from the power supply to the indicated hole in the terminal block.

4.Plug the terminal block into the 2-pin connector on the back of the camera and tighten the screw.

5.For safety, add a 1.0 A slow blow fuse to the positive wire from the power supply. The fuse should be less than 4 inches (10 cm) from the positive terminal on the power supply.

4 INCHES (10 CM) MAXIMUM

POWER

SUPPLY

Manual backgroundManual background +12 VDC

Manual background GND

INPUT

Figure 5. Connecting DC Power

C2944M-G (6/09)

13

Page 13
Image 13
Pelco C10DN manual Connecting Dc Power, Warnings