Pelco Installation Manual C1487M-H (1/01) 9
STEP 3 - INSTALL DOME DRIVE
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or Tables C through E in the Appen-
dix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
GREEN
TAB
RED
TAB
STEP 4 - INSTALL LOWER DOME
a. Snap the clip, on the end of the trim ring leash, into the hole on the
lip of the back box.
b. Line up the snaps on the trim ring with the mounting screws on the
back box. Snap the trim ring into the plastic snap washers on the
mounting screws.
TO USE YOUR DOME, REFER TO THE
OPERATION AND PROGRAMMING MANUAL.
+5 to +24 VDC
NOT USED
NOT USED
TX-
TX+
VIDEO IN
CONTROLLER
TX-
TX+
RX-
RX+
SWITCHES
(WIRING EXAMPLE)
1
2
3
4
5
6
7
ALARM
INPUTS
GROUND
+5 VDC
AUX 2 HEATER/FAN
(NOT USED)
VIDEO OUT
GROUND AUX 2
(NO)
(NC) RELAY
(AUX 1)
CONTROL
(RS-422)
LOGIC GATE
(WIRING EXAMPLE)
EXTERNAL RELAY
(WIRING EXAMPLE)
24 VAC
TRANFORMER
COAXITRON
CONTROLLER
2 WIRE
CONTROLLER
POWER
(24 VAC ONLY)
SPECTRA II ONLY
e. Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power.
The red LED will light.
IMPORTANT: If the LED does not light, refer to the
Trouble-
shooting
section.
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
LABEL
SW1
LABEL
SW2
SW1
SW2
RS-422 TERMINATION SWITCH
00303
ON
12345678
ON
12345678
SW2