C2403M-E (2/08) 9
Install Camera
1. Some indoor installations do not require a heater. If the
installation does not require a heater, remove the heater
board from the camera assembly. To remove the heater,
press on an end of the board.
2. 12 VDC operation only: The camera is set for 24 VAC
operation at the factory. For 12 VDC operation remove
the jumper from the 24 VAC position and install it in the
12 VDC position.
3. If the heater is installed, plug the heater connector from
the camera into the mating connector inside the base.
Plug the video connector from the camera into the
mating connector inside the base.
Turn on power to the camera and monitor.
4. Always make sure the tab on the camera bracket is
pointing out of the enclosure (away from the ceiling or
wall). Gently squeeze the bracket, place it against the
groove inside the back box, and then gently release.
Proper camera orientation:

WARNING: Heater elements could be hot! When camera power is on, use caution when

adjusting the camera. This applies to all models.

HEATER
BOARD
24 VAC JUMPER
12 VDC JUMPER
VIDEO
CONNECTOR
HEATER
CONNECTOR
VIDEO
CONNECTOR
HEATER
CONNECTOR
CAMERA BRACKET
TAB ALWAYS POINTS
OUT OF THE
ENCLOSURE
Wall Mounting: The camera braket
tab points out of the enclosure, and
the top of the camera points up
towards the tab.
CAMERA BRACKET
TAB ALWAYS POINTS
OUT OF THE
ENCLOSURE
TOP OF
CAMERA
Ceiling Mounting: The camera bracket tab
points out of the enclosure, and the top of
the camera is pointed in the opposite
direction.