IN-CEILING INSTALLATION: FIXED CEILING OR WALL

1.Cut a 4-inch diameter hole in the ceiling/wall (refer to Figure 6 on page 11).

2.Remove the surface mount ring from the back box (refer to Figure 5 on page 10).

a.Place your fingers on the circular marks located on the sides of the surface mount ring.

b.Pinch the sides.

c.Lift and remove the surface mount ring from the back box. Do not discard the surface mountring, it is required to complete the installation.

3.Connect the video cable and wires.

BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.

Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.

4.Connect the power wires (refer to Table C).

Table C. Power Input: In-Ceiling, Fixed Ceiling/Wall Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

 

 

 

AC Operation Only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switching between cameras.

5. Use 3-16 toggle bolts (not supplied) to attach the back box to the mounting surface.

Figure 6. In-Ceiling Installation to a Fixed Ceiling or Wall