Installation

The installation methods for the ICS090 Series include the following options:

Mount to the surface of a ceiling or wall

Install in a suspended ceiling

Install in a fixed ceiling or wall

Mount to the surface of a 4S standard electrical box

Install in a 4S deep electrical box

SURFACE INSTALLATION: CEILING/WALL

Refer to Figure 2 on page 8 for the following steps. Refer to Figure 3 on page 8 if you are installing the unit to the surface of a concrete ceiling or wall.

1.Pull the video and power wires through the ceiling/wall.

2.Connect the video cable and wires.

BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.

Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.

3.Connect the power wires (refer to Table A).

Table A. Power Input: Surface, Ceiling/Wall Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switching between cameras.