SURFACE INSTALLATION: 4S STANDARD ELECTRICAL BOX

1.Attach the adapter ring to the 4S box with two 8-32 x 1.00-inch screws (supplied; refer to Figure 7).

2.Connect the video cable and wires.

BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.

Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.

3.Connect the power wires (refer to Table D).

Table D. Power Input: Surface, 4S Standard Electrical Box Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

 

 

 

AC Operation Only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switching between cameras.

4.Attach the surface trim ring and back box to the adapter plate with two 8-32 x 2.50-inch screws (supplied).

4S STANDARD ELECTRICAL BOX

CEILING/

WALL

8-32 X 1.00

(SUPPLIED) OPTIONAL ADAPTER RING

8-32 X 2.50

BACK BOX AND

(SUPPLIED)

SURFACE MOUNT

 

RING

Figure 7. 4S Standard Electrical Box Installation

12

C2462M-E (3/09)

Page 12
Image 12
Pelco c2462m-e manual Surface Installation 4S Standard Electrical BOX, Standard Electrical Box Installation