SURFACE INSTALLATION: 4S STANDARD ELECTRICAL BOX
1.Attach the adapter ring to the 4S box with two
2.Connect the video cable and wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video
3.Connect the power wires (refer to Table D).
Table D. Power Input: Surface, 4S Standard Electrical Box Installation
Voltage | Red Wire | Black Wire |
|
|
|
12 VDC | + | Ground |
|
|
|
24 VAC | – | – |
|
|
|
AC Operation Only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.
NOTE: Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switching between cameras.
4.Attach the surface trim ring and back box to the adapter plate with two
4S STANDARD ELECTRICAL BOX
CEILING/ |
WALL |
(SUPPLIED) OPTIONAL ADAPTER RING
BACK BOX AND | |
(SUPPLIED) | SURFACE MOUNT |
| RING |
Figure 7. 4S Standard Electrical Box Installation
12 |