Pelco c2462m-e manual Service Connector, Attaching the 2.5 mm Monaural Headphone Plug

Models: c2462m-e

1 24
Download 24 pages 32.58 Kb
Page 20
Image 20

Service Connector

An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and adjustments. To use the cable, simply plug one end of the cable directly into the service connector of the ICS090, and then connect the other end to any standard BNC (VIDEO IN) connector on a monitor.

To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a local electronics supply store:

Qty Description

12.5 mm monaural headphone plug

1CPM 88 miniature coaxial connector

1RG174/U coaxial cable

To assemble the cable:

1.Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions supplied with the miniature coaxial connector.

2.Attach the 2.5 mm monaural plug to the other end of the coaxial cable (refer to Figure 15):

a.Remove the support sleeve from the plug, and then slip the support sleeve over the end of the cable.

b.Prepare the cable.

c.Solder the center connector of the cable to the center pin of the plug.

d.Thread the braid of the cable through the hole in the crimp pin, and then solder the braid to the top of the crimp pin.

e.Crimp the end of the crimp pin around the cable.

f.Reassemble the support sleeve and the plug.

CENTER CONDUCTOR

COAXIAL

 

 

CABLE

BRAID (SHIELD)

2.5 mm MONAURAL

 

 

HEADPHONE PLUG

Figure 15. Attaching the 2.5 mm Monaural Headphone Plug

20

C2462M-E (3/09)

Page 20
Image 20
Pelco c2462m-e manual Service Connector, Attaching the 2.5 mm Monaural Headphone Plug