Service Connector
An optional
To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a local electronics supply store:
Qty Description
12.5 mm monaural headphone plug
1CPM 88 miniature coaxial connector
1RG174/U coaxial cable
To assemble the cable:
1.Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions supplied with the miniature coaxial connector.
2.Attach the 2.5 mm monaural plug to the other end of the coaxial cable (refer to Figure 15):
a.Remove the support sleeve from the plug, and then slip the support sleeve over the end of the cable.
b.Prepare the cable.
c.Solder the center connector of the cable to the center pin of the plug.
d.Thread the braid of the cable through the hole in the crimp pin, and then solder the braid to the top of the crimp pin.
e.Crimp the end of the crimp pin around the cable.
f.Reassemble the support sleeve and the plug.
CENTER CONDUCTOR
COAXIAL |
|
|
CABLE | BRAID (SHIELD) | 2.5 mm MONAURAL |
|
| HEADPHONE PLUG |
Figure 15. Attaching the 2.5 mm Monaural Headphone Plug
20 |