Installation
.
1 Install the mount for the pendant dome. Refer to the instructions supplied with the mount.
2 Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. Pull power, alarm/auxiliary, and network cable into the back box.
The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for
Total | 20 AWG | 18 AWG | 16 AWG | 14 AWG |
VA | (0.5 mm2) | (1.0 mm2) | (1.5 mm2) | (2.5 mm2) |
36 | 79 ft | 125 ft | 199 ft | 316 ft |
| (24 m) | (38 m) | (60 m) | (96 m) |
|
|
|
|
|
88 | 32 ft | 51 ft | 81 ft | 129 ft |
| (9 m) | (15 m) | (24 m) | (39 m) |
|
|
|
|
|
NOTE: Input power for the dome is 24 VAC only. Power consumption is 36 VA per dome for indoor models and 88 VA for outdoor models. Use a 24 VAC transformer with a minimum output of 36 VA per dome for indoor applications and a minimum of 88 VA per dome for outdoor applications.
3 Screw the back box onto the mount. For outdoor installations, apply thread compound (provided) to the threads on the back box.
C2493M (12/05) | 3 |