Table C. Troubleshooting with Front-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

 

Corrective Action

 

 

 

 

 

 

 

 

Fiber Failover Mode LED (

 

 

)

 

 

 

 

 

 

 

 

 

 

 

 

 

Not lit

The module is not in

The FX Mode switch is set

If fiber redundancy is not

 

fiber redundancy

to position 0.

 

required, no action is

 

mode.

 

 

 

 

required. If fiber redundancy

 

 

 

 

 

 

is required, power off the

 

 

 

 

 

 

module, set the FX Mode

 

 

 

 

 

 

switch to position 1 or 2 as

 

 

 

 

 

 

appropriate, and then power

 

 

 

 

 

 

on the module. For detailed

 

 

 

 

 

 

information, refer to the

 

 

 

 

 

 

Setting Fiber Failover Mode

 

 

 

 

 

 

section.

 

 

 

 

 

 

Green

The module is in

The FX Mode switch is set

If fiber redundancy is

 

fiber redundancy

to position 1 (port A

 

required, no action is

 

mode. The primary

connects to the primary

required. If fiber redundancy

 

fiber link is

fiber link) or to position 2

is not required, power off the

 

operational. The

(port B connects to the

 

module, set the FX Mode

 

secondary fiber link

primary fiber link).

 

switch to position 0, and

 

is idle.

 

 

 

 

then power on the module.

 

 

 

 

 

 

Amber

The module is in

A problem exists with the

Refer to the Optic Fault LED

 

fiber redundancy

secondary fiber link. The

section or to the 100BASE-FX

 

mode. The primary

Optic Fault LED or the

 

Status LED section in this

 

fiber link is

100BASE-FX Status LED for

table as appropriate.

 

operational. The

port A or port B is red.

 

 

 

secondary fiber link

 

 

 

 

 

 

is down.

 

 

 

 

 

 

 

 

 

 

 

Flashing amber

The module is in

A problem exists with the

Refer to the Optic Fault LED

 

fiber redundancy

primary fiber link. The Optic

section or to the 100BASE-FX

 

mode. The primary

Fault LED or the

 

Status LED section in this

 

fiber link is down.

100BASE-FX Status LED for

table as appropriate.

 

The secondary fiber

port A or port B is red.

 

 

 

link is operational.

 

 

 

 

 

 

 

 

 

 

 

Red

The module is in

A problem exists with the

Refer to the Optic Fault LED

 

fiber redundancy

primary and backup fiber

section or to the 100BASE-FX

 

mode; however, both

links. The Optic Fault LEDs

Status LED section in this

 

primary and

or the 100BASE-FX Status

table as appropriate.

 

secondary fiber links

LEDs for ports A and B are

 

 

are down.

red.

 

 

 

 

 

 

 

 

 

(Continued on next page)

C2624M (6/07)

23

Page 23
Image 23
Pelco C2624M manual Meaning