Pelco C3425M-D manual In-Ceilinginstallation Fixed Ceiling/Wall

Models: C3425M-D

1 32
Download 32 pages 39.3 Kb
Page 13
Image 13
IN-CEILING INSTALLATION: FIXED CEILING/WALL

4.Remove an adjacent ceiling tile to access the unit.

5.Connect the video cable/wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Blue wire = Video +

Gray wire = Video -

6. Connect the power wires.

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

7. Reinstall the adjacent ceiling tile.

IN-CEILING INSTALLATION: FIXED CEILING/WALL

1.

Remove the surface mount ring from the back box (refer to Figure 5 on page 11):

 

 

a.

Place fingers on the circular marks located on the sides of the surface mount ring

.

 

b.

Pinch the sides.

 

 

 

 

c.

Lift and remove the surface mount ring from the back box. Do not discard the surface mount

 

 

ring; it is required to complete the installation.

 

2.

Cut a hole 4 inches (10 cm) in diameter in the ceiling/wall (refer to Figure 8 on page 14).

 

3.

Pull video and power wires through the opening.

 

4.

Connect the video cable/wires:

 

 

BNC: Connect the BNC connector from the unit to a mating BNC connector.

 

 

UTP: Blue wire = Video +

 

 

 

 

Gray wire = Video -

 

5.

Connect the power wires.

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Red Wire

Black Wire

 

 

 

 

 

 

 

 

 

 

 

12 VDC

+

Ground

 

 

 

 

 

 

 

 

 

 

 

24 VAC

~

~

 

 

 

 

 

 

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

C3425M-D (8/08)

13

Page 13
Image 13
Pelco C3425M-D manual In-Ceilinginstallation Fixed Ceiling/Wall