10 Pelco Manual C490M-D (1/96)
8.0 SPECIFICATIONS
MECHANICAL
Window: 1/2" (12.7 mm) thick impact and
abrasion resistant clear Lexan
Camera
Mounting: Adjustable tilt table
Maximum
Camera/Lens
Size: Accepts camera/lens combinations
(including BNC connector) up to:
12.0" L x 6.0" W x 6.0" H
(30.48 cm x 15.24 cm x 15.24 cm)
Enclosure
Mounting: Twelve (12) .390" (0.99 cm) diam-
eter holes on protected rear surfaces
(top and back)
Security: Tamper-resistant screws
N.O./N.C. switch contact on cover
Tamper Switch: Plunger type door switch with “pull
to cheat” feature. N.O./N.C. contacts
clearly marked on body of switch.
DM electrical rating: 10A, 125V.
Plunger type with .20" (0.51 cm)
ELECTRICAL
Cable Entry: Six-position terminal block. Cable
entry access through back and top
Tamper Switch: 1/4" (.63 cm) quick connect. N.O./
N.C. clearly marked on switch body.
10A, maximum switching current
125V, maximum switching voltage.
GENERAL
Construction: Formed 10 gauge .134" (0.34 cm)
steel
Finish: Poly vinyl powder coat
Dimensions: See Figure 1
Environment: Indoor, 32° to 120° F (0° to 48.89° C)
Unit Weight: 40 lbs 13 oz (18.36 kg)
9.0 MODELS
The HS1000 high-security corner mount enclosure has
been designed for installations such as parking garages,
prisons, detention cells and many other areas requiring
maximum protection from vandalism. Below is a list
of available HS1000 enclosure options.
9.1 OPTIONS
HS1000H Hood for mid-wall mounting of
HS1000 enclosure.
HB6000 120 VAC thermostatically controlled
heater and blower.
Provides 80 watts of heat: activates
ON at 40°F (4.44° C); and OFF at
60°F (15.56° C).
Provides internal air circulation: ac-
tivates ON at 110°F (43.33° C); and
OFF at 80°F (26.67° C).
HB6000/220 Same as HB6000 except operates at
230 VAC.
HB6024 Same as HB6000 except operates at
24 VAC.