Pelco C554M-A (5/98) Preset Power-up Routine, Creating Presets, Auto/Random Operation

Models: C554M-A (5/98)

1 28
Download 28 pages 21.81 Kb
Page 22
Image 22
4.0 OPERATION

4.0 OPERATION

4.1 Preset Power-up Routine

When a pre-position Coaxitron® receiver is first powered up, it goes through a rou- tine that orients itself to the pan/tilt and lens connected to it.

The routine first automatically operates the lens zoom and focus functions. The pan/tilt will tilt up and down (nod yes) if the receiver reads feedback voltages (indi- cating a pre-position lens) or pan left and right (nod no) if it does not read any feedback voltages (indicating a manual lens).

The second part of the routine will operate the pan left and pan right functions. The pan/tilt will tilt up and down (nod yes) if it reads only one feedback voltage (indicat- ing a pan/tilt with limit stops.) The pan/tilt will pan left and right (nod no) if it reads two feedback voltages (indicating a SL pan/tilt.)

This routine is a good troubleshooting indicator that the control cable has been wired properly. The total routine takes approximately 45 seconds to complete.

4.2 Creating Presets

Coaxitron® controllers capable of creating presets include the CM6700, CM7500, CM8500, CM9500, and CM9760-CXT. Refer to the installation operation manual for the Coaxitron® controller you are using when creating presets.

Refer to Figure 3 and Tables B, C, and D when assembling pin-to-pin wiring con- nections from preset domes, pan/tilts and lenses to the Coaxitron® receiver.

4.3 Auto/Random Operation

The A9000 Auto/Random Scan module is a plug-in PC board option for Coaxitron® receiver/drivers. This module provides auto scan and random scan modes for auto- matically controlling pan and tilts within preset limits. The random scan and auto scan functions are controlled by a MPT9000 Series controller.

Advantages of random scan:

1.Because the scan direction, scan period, and dwell period are unpredictable, unauthorized activities or intrusions are discouraged.

2.Because of the reduced duty cycle, gear train wear, cable fatigue, drive motor wear, and temperature rise are reduced. These factors all contribute to higher system reliability and increased equipment life.

Refer to the A9000 manual for installation and operation instructions.

22

Pelco Manual C554M-A (5/98)

Page 22
Image 22
Pelco C554M-A (5/98) Preset Power-up Routine, Creating Presets, Auto/Random Operation, Pelco Manual C554M-A 5/98