Pelco Manual C680M-G (7/01) 21
Relay Operation
When an alarm input is activated, a 20-second countdown begins before the relay turns on
the warning light or buzzer. The numbers appear on the screen. This is an entry feature that
allows you to disarm the alarm when you enter your own premises.
Once the relay operates, the light or buzzer remains on until you manually turn off the relay.
Turning Off the Relay
1. Press and hold the Function button. The Function Key List appears. Keep holding the
Function button.
FUNCTION KEY LIST
0 : Setup
1 : Camera 1 recording/stop
2 : Camera 2 recording/stop
3 : Camera 3 recording/stop
4 : Camera 4 recording/stop
5 : All the cameras recording
6 : All the cameras stop
: Alarm On
: Alarm Off
2. Press and release the Search forward (>>) button, and then release the Function
button.
The relay is now turned off.
If you are manually controlling the operation of the relay, another alarm will not activate the
relay. To arm the relay again, refer to the procedure in this section under

Arming the Relay

.
If the relay has been programmed to operate in the Alarm Output menu, another alarm will
operate the relay as long as it is still within the programmed time period.