![3.1 OPTIONS](/images/new-backgrounds/15826/158263x1.webp)
3.1 OPTIONS
DT200 | Dual desktop mount kit; two units |
| can be mounted |
| desktop chassis. |
R300 | Rack mounting kit. Up to three (3) |
| units may be racked horizontally In a |
| single rack kit. Blank filler panels |
| provided for use when less than three |
| units are racked. |
4.0 OPERATION
Optimum performance Is achieved if an oscilloscope a standard EIA resolution chart are used in making gain and boost adjustments. The (GAIN control should be adjusted for an output level of 1 volt
If the use of a resolution chart is precluded, the H.F. BOOST control should be adjusted for maximum sharp- ness of sync pulse
In the absence of an oscilloscope, a less precise (but often equally satisfactory) adjustment can be made as follows:
1.Set the GAIN and BOOST controls approximately 1/3 turn from fully counterclockwise.
2.Adjust GAIN control for satisfactory overall pic- ture contrast.
3.Adjust L.F. BOOST control for optimum detail. Too much boost (clockwise) can cause picture in- stability and/or smearing (trail).
4.Adjust the H.F. BOOST control to further optimize picture detail. Note that the effectiveness of this control is hardly perceptible unless very fine pic- ture detail is present in the camera signal output. An excessive setting of this control (clockwise) can, however, increase picture noise.
Refer to Figure 1 for a typical system configuration.
OUTPUT | INPUT |
12 VAC
Figure 1. Typical System Configuration
2 | Pelco Manual C630M Rev A (8/90) |