Pelco Manual C306M-K (4/05) 11
8Turn on the power. If the red LED lights, turn off the power and proceed to the next
step. If the red LED does not light, refer to the
Troubleshooting
section.
9Plug the male Esprit system connector, located on the bottom of the pan and tilt, into
the female Esprit system connector located on the transformer module. Align the pan
and tilt part number with the alignment label of the base and then attach the pan and
tilt to the base with three 1/4-20 nuts and washers (supplied).
10 Set the receiver address and system baud rate by configuring DIP switches SW1 and
SW2.
To set the DIP switches:
a. Remove the plug from the left cover of the pan and tilt. It is not necessary to re-
move the pan and tilt cover.
b. Set the baud rate (SW1) and receiver address (SW2). For switch settings refer to
the labels located on the inside lid of the housing or Tables A and B in the
Appendix
.
c. Replace the plug.
NOTE:
Switch settings
have no effect on Coaxitron
control signals. The Esprit
will sense and automatically
select input from Coaxitron
control signals in either
standard or extended mode.
PART
NUMBER
ALIGNMENT
LABEL
MALE SYSTEM
CONNECTOR
FEMALE
SYSTEM
CONNECTOR