Pelco FR8304 manual Laser has reached end of, Refer to the Optic Fault LED

Models: FR8304

1 24
Download 24 pages 25.22 Kb
Page 17
Image 17

Table A. Troubleshooting with Front-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

 

Video Present LED (Continued)

 

 

 

 

 

Red on receiver

Incoming video

Optical signal is not being

Refer to the Optic Fault LED -

 

signal is not present

received from the trans-

Receiver section in this

 

on the channel.

mitter. Optic Fault LED is

table.

 

 

also red.

 

 

 

 

 

 

 

Video source is not

Check power connection to

 

 

powered on.

the video source.

 

 

 

 

 

 

Video source is not

Check BNC connections.

 

 

connected to the

 

 

 

transmitter.

 

 

 

 

 

 

 

Coaxial cable connected to

Replace cable.

 

 

the transmitter is defective.

 

 

 

 

 

 

Optic Fault LED - Transmitter

 

 

 

 

 

Green

Laser is operating

No action required.

 

properly.

 

 

 

 

 

 

Flashing red

Laser has shut down.

Transmitter is operating in

Ensure that transmitter oper-

 

 

extreme environmental

ates according to operating

 

 

conditions; for example,

conditions stated in the

 

 

operating temperature is

Specifications section, and

 

 

below or above recom-

then cycle the power.

 

 

mended range as stated in

If problem persists, contact

 

 

the Specifications section.

Product Support.

 

 

 

 

 

 

Laser has reached end of

Cycle the power. If problem

 

 

life.

persists, contact Product

 

 

 

Support.

 

 

 

 

 

 

 

(Continued on next page)