Installation

Installation

The following items are supplied:

1HS4514 Series enclosure

1#10 socket for tamper-resistant screws (1/4-inch drive tool is not provided)

1Three-pin plug with leads (included with -1/-2 models with heater)

21/4-20 Phillips screws (to mount enclosure)

1 Steel eyebolt

ENCLOSURE MOUNTING

1.Place the enclosure on a flat surface with the top facing up. Open the enclosure using the following procedure:

a.Remove the four tamper-resistant screws securing the enclosure cover using the #10 socket for tamper-resistant screws (provided) and your 1/4-inch drive tool. (Drive tool is not provided.)

b.Separate the top and bottom enclosure sections.

2.Remove the camera sled from the rail by loosening the two 10-32 Phillips screws and sliding the sled to the rear.

3.Install two wiring fittings in the bottom of the enclosure.

If the enclosure is installed outdoors, be sure that watertight fittings are installed. If conduit or other wiring fittings are used, be sure the fittings are sealed to prevent water from getting inside the enclosure.

WARNING: To maintain watertight standards, proper cabling must be used when wiring the enclosure. Use of flat cable or multiple cables will prevent the proper seal of connectors. Outdoor rated sheathing should cover multiple cables.

4.Reassemble the top and bottom enclosure sections and lift the enclosure into place for mounting.

Optional: The enclosure can easily be lifted with the optional steel eyebolt (eyebolt included). Install the steel eyebolt and lift the enclosure using the following procedure:

a.Remove the Phillips screw and washer from the captive nut located in the back of the enclosure. Set the Phillips screw aside.

b.Install the steel eyebolt in the captive nut. Firmly tighten but do not overtighten.

c.Attach a hoist line to the steel eyebolt. Be sure the hoist line and any lifting hardware are sufficiently strong enough to support the weight of the enclosure. Hoist the enclosure into place.

5.Locate the two threaded mounting holes on the bottom of the enclosure. Using two 1/4-20 screws that do not exceed 5/8-inch (1.59 cm) in length (not supplied with the enclosure), mount the enclosure to a fixed mount.

If you lifted the enclosure with the aid of the steel eyebolt, remove the eyebolt and reinstall the Phillips screw and washer.

6.After the enclosure is mounted, opening the enclosure is more convenient using the following procedure:

a.Remove the two tamper-resistant screws securing the front of the enclosure cover.

b.Loosen, but do not remove, the two tamper-resistant screws securing the rear of the enclosure cover.

c.Push the top of the enclosure back approximately 1/4-inch (0.63 cm) and flip the top open.

d.Reverse the procedure to close.