Service Connector
The IS310 Series Camclosure integrated camera system includes a service connector that outputs camera video. Use it at the installation site to set up the field of view and focus the camera.
SERVICE
CONNECTOR
Figure 13. Service Connector
Pelco offers two optional items that plug directly into the service connector: CST150 compact field tool and IS-SC cable.
•The optional CST150 compact field tool has a
NOTE: The three buttons on the CST150 are not used with the IS310 Series Camclosure.
•The optional
To assemble a longer service cable for the Camclosure integrated camera system, purchase the following items from a local electronics supply store:
Qty Description
12.5 mm monaural headphone plug
1CPM 88 miniature coaxial connector
1RG174/U coaxial cable
To assemble the cable:
1.Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions supplied with the miniature coaxial connector.
2.Attach the 2.5 mm monaural plug to the other end of the coaxial cable (refer to Figure 14):
a.Remove the support sleeve from the plug. Slip the support sleeve over the end of the cable.
b.Prepare the cable. Solder the center connector of the cable to the center pin of the plug. Thread the braid of the cable through the hole in the crimp pin.
c.Solder the braid to the top of the crimp pin. Crimp the end of the crimp pin around the cable. Reassemble the support sleeve and the plug.
CENTER CONDUCTOR
COAXIAL
CABLEBRAID (SHIELD)2.5 MM MONAURAL
HEADPHONE PLUG
Figure 14. Attaching the 2.5 mm Monaural Headphone Plug
17 |