Pelco IV SE SERIES manual Ac/Dc, Wire Gauge, Total VA, Receiver

Models: IV SE SERIES

1 16
Download 16 pages 6.74 Kb
Page 3
Image 3

1.Using the back box as a template, mark the fastener positions on the mounting surface.

2.Prepare the mounting surface. Pull power and video wire/cable for the dome system. Refer to Table A, Table B, and Table C for wiring distances.

3.Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. Pull wiring into the back box.

.

Table A. Video Coaxial Cable Requirements

Cable Type*

Maximum Distance

 

 

RG59/U

750 ft (229 m)

 

 

RG6/U

1,000 ft (305 m)

 

 

RG11/U

1,500 ft (457 m)

 

 

*Cable requirements: 75 ohms impedance

All-copper center conductor All-copper braided shield with 95% braid coverage

Table B. 24 VAC/24VDC Wiring Distances

The following are the recommended maximum distances for 24 VAC and 24 VDC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC- or DC-powered devices.)

AC/DC

 

Wire Gauge

 

Total VA/

20 AWG

18 AWG

16 AWG

14 AWG

Total Watts

(0.5 mm2)

(1.0 mm2)

(1.5 mm2)

(2.5 mm2)

23 VA/

123 ft

196 ft

311 ft

495 ft

15 watts

(38 m)

(60 m)

(95 m)

(151 m)

 

 

 

 

 

NOTE: Input power for the dome is 24 VAC or 24 VDC. Using 24 VAC input power, power consumption is 23 VA per dome. Using 24 VDC input power, power consumption is 0.7 A (15 watts). Use a 24 VAC transformer with a minimum of 40 VA per dome.

.

Table C. UTP Wiring Distances

Receiver

Maximum Distance

 

 

Active

0-3,000 ft

(Video Only)

(0-914.4 m)

 

 

Passive

0-750 ft

(Video, Coaxitron, Pelco V-Sync)

(0-228.6 m)

 

 

NOTE: As a minimum, UTP requires Cat5, 100-ohm twisted pair cable.