Pelco Manual C671M (1/01) 29
CLOCK OUT Sets at the CLOCK OUT terminal the number of frames or fields being
recorded (depending on the recording mode).
1. First, set the recording mode for the CLOCK OUT pulse output in
the Rear Terminal menu.
•REC – When recording in any mode
•T/L REC – When recording in time-lapse mode (L24H, L40H)
2. Second, select the frequency interval by turning the JOG dial,
switching the display in the following order: 1, 2, 3, 4, 5, 10, 15,
20, 25, 30, 50, 60, F (field), 1. The numbers from 1 to 60 indicate
the number of frames in 8H recording mode and the number of
fields in time-lapse recording modes. One frame consists of two
fields. One field is selected when set to F (field).
MODE OUT Sets the state in which the signal output at the MODE OUT terminal is
switched to active. When you turn the JOG dial, the display switches in
the following order, and under the following circumstances:
•REC – During recording.
•PLAY – During playback.
•POWER – While the VCR is turned on.
•TAPE IN – When you insert a tape in the VCR.
•TAPE REMAIN – When the tape has about nine minutes left (in
8H mode).
•CLOCK ADJ – When the clock indicates 00:00
(minutes:seconds), output the signal for one second only.
REC IN Sets the REC IN terminal’s operating mode.
•SERIES – Recording starts when the signal is input.
•REC-START/STOP – Recording continues while the signal is
input. Recording may not start if the input period is short.
MAINTENANCE MENURefer to the
Maintenance
section for instructions and procedures.