Pelco Manual C671M (1/01) 27

RECORDING SET UP MENU
Refer to the

Programming for Alarm Recording

section for programming instructions for the
following fields.
NOTE:

When using the MX4000 Series Genex Multiplexer, set ALARM REC DURATION

to MAN2, and make sure EMERGENCY REC is set ON if the VCR is to record alarms only.

ALARM REC MODE Sets the alarm recording mode. When you turn the JOG dial,
the display switches in the following order: 8H, L24H, L40H, 8H.
ALARM REC DURATION Sets the length of the alarm recording period. When you turn
the JOG dial, the display switches in the following order: 1M
(minute), 2M, 5M, 10M, MAN1, MAN2, 15S (second), 30S,
45S, 1M.
EMERGENCY REC Sets the emergency recording mode, as follows:
ON – Starts alarm recording when the alarm signal is
received (ALM IN terminal grounded), not only during
recording but also when the power is off, when the tape
is stopped, or when the VCR is in standby mode for
timer recording.
OFF – Starts alarm recording when the alarm signal is
received (ALM IN terminal is grounded) during
recording.
CLOG DETECT Sets clog detection mode, as follows:
ON – The VCR automatically removes particles that
may accumulate on the heads during time-lapse
recording. If they cannot be entirely removed, the
warning CLOG flashes on the fluorescent display.
OFF – The VCR does not detect a clogged head.
<RECORDING SET UP>
ALARM REC MODE
ALARM REC DURATIO
N
EMERGENCY REC
CLOG DETECT

Figure 16. Recording Set

Up Menu