SAFETY INSTRUCTIONS
GROUNDING
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electrical shock. This system is equipped with a cord having an
DANGER – Improper connection of the
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system should only be connected to a properly grounded,
EXTENSION CORDS
If an extension cord is necessary, use only
Exercise caution when arranging the cord so that it will not be tripped over or pulled. Do not use damaged extension cords. Examine extension cord before using and replace if damaged. Do not abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always grasp the plug and pull to disconnect.
WARNING – Always
1.READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2.DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of this system. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself; refer to an authorized service facility.
3.CAUTION - Do not operate with broken or faulty parts as this may result in exposure to ultraviolet radiation. Contact supplier for replacement parts.
4.Do not operate the system if it has a damaged cord or plug, or if it is malfunctioning or if it has been dropped or damaged in any manner.
5.Always unplug the system, release water pressure before servicing or cleaning. Never yank cord to remove from outlet; grasp the wall plug and pull to disconnect.
6.Do not use the system for other than intended use. The use of attachments not recommended or sold by the manufacturer may cause an unsafe condition.
7.To prevent risk of electrical shock, connect this system only to a properly grounded,
8.Visually inspect this system prior to installation. If the quartz sleeve or lamp is broken, cracked or damaged in any way, do not use. Contact the supplier for replacement parts.
9.Keep all connections dry and off the ground. Do not touch plug with wet hands.
10.The light emitted by the lamp will cause serious eye damage and burn unprotected skin. Do not plug system into an electrical outlet without first properly securing the lamp into the chamber. Unplug the system prior to removing the lamp from the chamber.
11.If the UV system malfunctions or fails, water must be boiled prior to consumption until the UV system is operational and the water lines have been shocked. System failure is indicated by the system’s audible and visual alarms or the absence of any indicator light.
12.Intended for indoor use only. System must not be exposed to weather elements. In seasonal applications, chamber must be drained to prevent freezing.
13.Installation of this system must be in accordance with local plumbing and electrical codes as well as any and all applicable regulations and laws.
14.The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, are also not to handle the UV system unless they have been given supervision
or instruction.
15.SAVETHESE INSTRUCTIONS.
WARNING – To prevent risk of electrical shock, connect this system only to a properly grounded, grounding- |
|
type power supply receptacle that is protected by a Ground Fault Circuit Interrupter. Pull plug before servicing |
|
or replacing lamp. Keep all connections dry and off the ground. Do not touch plug with wet hands. |
|
WARNING – Do not look directly at UV lamp when it is operating. The light emitted by the lamp will cause |
|
serious eye damage and burn unprotected skin. |
|
WARNING – Read manual before installing or servicing this system. Only authorized personnel possessing |
|
a strong understanding of this system should attempt to replace lamp or service this system. |
|
WARNING – Always |
|
NOTE – Maximum pressure rating is 125 PSI (8.62 bar) | 1 |
|