OVERVIEW
INSTALLATION
SPECIFICATIONS
General (All Models)
Operating Parameters |
|
Maximum operating pressure | 125 PSI (862 kPa) |
Minimum operating pressure | 4 PSI (27.5 kPa) |
Maximum ambient air temperature | 122 0F (500C) |
Minimum ambient air temperature | 320F (00C) |
Maximum humidity | 100% |
Maximum hardness | 120 ppm |
| (7 grains per gallon) |
Maximum iron | 0.3 ppm |
Minimum UVT | 70% |
Installation | Vertical or horizontal* |
Flow Restrictor | Yes |
NSF Certification | NSF Standard 55 |
| Class B |
Rated service life of lamp | 1 year |
Certification (other) |
|
OPERATION
Flow Rates
Rated flow for NSF Std 55, Class B
Electrical
8.9 gpm | 8.9 gpm | 15.8 gpm |
(33.7 lpm) | (33.7 lpm) | (59.8 lpm) |
MAINTENANCE
WARRANTY
Voltage | |||
Frequency | |||
Max. current | 0.5 Amp | 0.5 Amp | 0.85 Amp |
Max. power | 50 Watts | 50 Watts | 83 Watts |
consumption |
|
|
|
Lamp power | 40 Watts | 40 Watts | 70 Watts |
Other |
|
|
|
UV Chamber Material | 304 SST | 304 SST | 316 SST |
Inlet/Outlet | 3/4" NPT | 3/4" NPT | 1" NPT |