OVERVIEW

INSTALLATION

SPECIFICATIONS

General (All Models)

Operating Parameters

 

Maximum operating pressure

125 PSI (862 kPa)

Minimum operating pressure

4 PSI (27.5 kPa)

Maximum ambient air temperature

122 0F (500C)

Minimum ambient air temperature

320F (00C)

Maximum humidity

100%

Maximum hardness

120 ppm

 

(7 grains per gallon)

Maximum iron

0.3 ppm

Minimum UVT

70%

Installation

Vertical or horizontal*

Flow Restrictor

Yes

NSF Certification

NSF Standard 55

 

Class B

Rated service life of lamp

1 year

Certification (other)

 

OPERATION

Flow Rates

Rated flow for NSF Std 55, Class B

Electrical

PUV-Basic

PUV-8

PUV-16

8.9 gpm

8.9 gpm

15.8 gpm

(33.7 lpm)

(33.7 lpm)

(59.8 lpm)

MAINTENANCE

WARRANTY

Voltage

100-240V AC

100-240V AC

100-240V AC

Frequency

50-60 Hz

50-60 Hz

50-60 Hz

Max. current

0.5 Amp

0.5 Amp

0.85 Amp

Max. power

50 Watts

50 Watts

83 Watts

consumption

 

 

 

Lamp power

40 Watts

40 Watts

70 Watts

Other

 

 

 

UV Chamber Material

304 SST

304 SST

316 SST

Inlet/Outlet

3/4" NPT

3/4" NPT

1" NPT