4&"-"/5

YOU WILL NEED TO SUPPLY:

• Impervious Shims/Spacers (12 to 20)

• Finish nails, 1" brads

3/16" x 2-1/2" concrete screws (for masonry installation)

Closed cell foam backer rod/sealant backer (12 to 30 ft.)

• Pella® SmartFlashfoil backed butyl window and door flashing tape or equivalent

• Great Stuff Window and Door Insulating Foam Sealant by the Dow Chemical Company or equivalent low pressure polyurethane window and door foam - DO NOT use high pressure or latex foams.

• OSI Quad Multi-Polymer sealant or equivalent high quality exterior grade polyurethane or silicone sealant.

(1 tube per window)

TOOLS REQUIRED:

Tape measure

Level

Square

Hammer or Finish Nailer

• Stapler

• Scissors or utility knife

Drill with a #2 Phillips (at least 4" long) and #3 square drive bit (provided in cable clamp kit)

• 1/2" open end wrench

3/16" wrench or socket

Sealant Gun

Installation will require two or more persons for safety reasons.

LEGEND - STEPS REQUIRED OF:

ALL

REPL APPS

NEW CONST

=All applications

=Replacement applications

=New Construction applications

REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.

1ROUGH OPENING PREPARATION

Water Resistive Barrier

1C

1st cut

 

ALL

A. Remove all packaging from the window.

3rd cut

 

 

 

 

 

 

 

APPS

 

B.

REPLACEMENT APPLICATIONS: Remove the

 

REPL

 

 

existing, window, trim, insulation and sealant from the

 

 

 

opening.

 

 

 

 

 

 

CONST

 

C. NEW CONSTRUCTION APPLICATIONS: Cut the

 

NEW

 

 

water resistive barrier. Fold the side flaps into the opening

 

 

 

and staple to inside wall.

 

 

 

 

 

 

 

D. Confirm the window will fit the opening. Measure all

 

ALL

 

 

 

 

four sides of the opening to make sure it is 3/4" larger

 

ALL

 

 

than the window in both width and height. Measure the

 

 

 

width and height in several places to ensure the header

 

 

 

 

 

ALL

 

 

and studs are not bowed.

 

 

 

Note: 1-1/2" or more of solid wood blocking is required

 

ALL

 

 

 

 

 

around the perimeter of the opening. Fix any problems

 

ALL

 

 

with the opening before proceeding. If installing new

 

 

 

blocking, install the blocking so it’s flush with the

 

 

 

 

 

ALL

 

 

exterior sheathing of the house. DO NOT attempt to

 

 

 

install a window in an under size opening.

 

ALL

 

 

 

 

 

 

 

ALL

 

E.

Confirm the opening is plumb and level.

 

 

 

 

ALL

 

 

Note: It is critical the bottom is level.

 

 

 

 

 

2nd

cut

1D

1E

Page 2
Image 2
Pella 81470102 1ROUGH Opening Preparation, Remember to USE Appropriate Personal Protective Equipment