Pentair 100 Ventilation, Outdoor Installation Only, Outdoor Vent Cap Installation

Models: 100

1 40
Download 40 pages 37.49 Kb
Page 17
Image 17
VENTILATION

Installation (contd.)

17

VENTILATION

OUTDOOR INSTALLATION ONLY

(See additional instructions for outdoor Power- Max units in PowerMax Appendix)

For outdoor installation with built in vent top, the heater must be placed in a suitable area on a level, noncombus- tible surface. Do not install the heater under an overhang with clearances less than 3 feet from the top of the heater. The area under an overhang must be open on three sides.

IMPORTANT!

In an outdoor installation it is important to protect your heater from water damage. Ensure water is diverted from overhanging eves with a proper gutter/ drainage system. The heater must be set on a level foundation for proper rain drainage.

Maintain minimum clearances as indicated below. Install a minimum of 4 feet below, and 4 feet horizontally from any opening to a building.

The heater should not be installed closer than 6 inches to any fences, walls or shrubs at any side or back, nor closer than 18 inches at the plumbing side. A minimum clearance of 24 inches must be maintained at the front of the heater.

 

6"

DOOR

6"

 

24"

 

 

18"

Figure 18.

IMPORTANT!

When locating the heater, consider that high winds can roll over or deflect off adjacent buildings and walls. Normally, placing the heater at least three feet from any wall will minimize downdraft.

Unusually high prevailing wind conditions and downdrafts may require the use of a stack type outdoor vent kit (available at additional cost).

NOTE

This unit shall not be operated outdoors at temperatures below 0o F. for propane and -20oF. for natural gas.

STACK TYPE OUTDOOR VENT KIT

Model

Vent Cap

Product No.

Vent Dia.

 

150

OV15

460237

6 in.

 

195/200

OV20

460222

7 in.

 

250

OV25

460223

7 in.

 

300

OV30

460224

8 in.

 

350

OV35

460225

9 in.

 

400

OV40

460226

10 in.

Table 9.

 

 

 

 

 

Outdoor Stack

 

 

Top Cover

Flue Adaptor

Inner Panel

Flue Collector

Figure 19.

Figure 20.

OUTDOOR VENT CAP INSTALLATION

The MiniMax Plus heater is shipped standard as an outdoor stackless unit. To install the outdoor vent kit:

1.Take out the louvered outer top after first removing all 1/4 in. sheet metal screws attaching it along its perimeter to the cabinet. Set it aside.

2.Place the flue adaptor over the flue collector opening. Temporarily, put the top cover, from the kit, on with the label to the front of the heater. Center the flue adaptor evenly inside the top cover flue stack opening. Remove the top cover and secure the centered flue adaptor to the inner panel with the provided #8 x 1/2 in. drill qwik screws.

3.Place the top cover, with the hole for the stack, on the heater cabinet.

4.Install the vent stack through the hole in the top cover, over the flue adaptor top ring.

5.Using a 3/32 in. drill bit, position the “L” bracket to hold the top cover and outdoor stack. Drill the pilot holes through the “L” bracket holes to accept the screws.

6.Secure the vent stack and the inner top with the #8

x1/4 in. sheet metal screws through the “L” brackets.

Rev. G 1-22-04

P/N 471048

Page 17
Image 17
Pentair 100 installation manual Ventilation, Outdoor Installation Only, Outdoor Vent Cap Installation, Installation contd