Section 3

User Maintenance

The following information describes how to service and maintain the IntelliFlo pump.

Pump Strainer Basket

The strainer, sometimes referred to as the “Hair and Lint Pot,” is in front of the of the pump. Inside there is a basket which must be kept clean of leaves and debris at all times. View the basket through the top see through lid to inspect for leaves and debris.

Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and possibly the heater.

Pump Strainer Basket WARNING — DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and that the strainer pot is cool to the touch, then open with extreme caution.

Pump Strainer Basket Service CAUTION — To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer baskets regularly.

Pump Strainer Basket Service

If the IntelliFlo pump is installed below the water level of the pool, close the return and suction lines before opening the hair and lint pot on the pump.

1.Press the Stop button to stop the pump and switch off the pump at the circuit breaker.

2.DisconnectthecommunicationcablefromtheIntelliFlo4pump.

3.Relievepressureinthesystem.

4.Turn theclamp and lidina counterclockwise direction until it stops.

5.Remove the clamp and lid.

6.Remove the basket and put the debris into the trash and rinse out the basket. If the basket is cracked, replace the basket.

7.Replace the basket and fill the pump pot and volute with water up to the inlet port.

8.Cleanthecover,o-ring,andsealingsurfaceofthepumppot.Grease theo-ringwithTeflonorsiliconelubricant.

9.Reinstall the lid by placing the clamp and the lid on the pot.