To remove the IntelliFlo 4 drive and control panel from the motor assembly:

1.Make sure all electrical breakers and switches are turned off before removing the drive.

2.Disconnect the RS-485 communication cable from the pump.

3.Open the control panel cover.

4.Remove the three Phillips head screws securing the drive to the motor assembly as shown.

CAUTION: TO AVOID ELECTRICAL HAZARD, DO NOT REMOVE THE FOUR TAMPER PROOF BITS FROM THE MOTOR ASSEMBLY

5.Lift up the drive assembly and remove it from the motor adapter located on top of the motor assembly.

Note: Be careful not to remove the gasket between the drive and motor, it is critical in keeping moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or missing gasket.

To install the IntelliFlo drive assembly onto the motor assembly:

1.Make sure all electrical breakers and switches are turned off before installing the drive.

2.Be sure that the gasket between the drive and motor is in place. It is critical in keeping moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or missing gasket.

3.Verify that the three (3) orange motor post caps are in position before placing the drive on the motor assembly.

4.Align the drive assembly with the motor adapter and seat the drive on the motor assembly.

5.Secure and tighten the drive assembly with the three Phillips head screws.

Phillips head screw

Phillips head screws

Do not remove

Adapter connector

these screws

 

Orange motor post caps (QTY. 3)