SYSTEM INDICATOR LIGHTS
POWER | REMOTE | |
| ||
PRESSURE SW | POOL | |
| ||
| SPA | |
THERMOSTAT |
|
|
| OFF | |
HEATING | TEMPERATURE | SETTING |
SERVICE | POOL | SPA |
| PRESS ANY ARROW ONCE TO | |
| CHECK SET TEMPERATURE |
Figure 7.
REMOTE BUTTON
POOL BUTTON
SPA BUTTON
OFF BUTTON
TEMP. UP
SPA AND POOL TEMPERATURE SET BUTTONS
TEMP. DOWN
SECTION III. INTRODUCTION OF DDTC
The DDTC board, shown in Figure 7, is a digital temperature controller capable of controlling the pool, spa or both to a minimum temperature of 65° F. (below 65° F. display reads "Off") and a maximum of 104° F. The DDTC board also functions as a system status indicator, using LED lights and programmed error codes.
During normal operation, the DDTC will display the current temperature of the water returning to the heater, depending on which mode has been selected, “Pool” or “Spa”. This is accomplished by a thermister (sensor) on the inlet port of the water header of the heater and working in conjunction with the internal microprocessor controlling the operation of the heater.
Changing the desired pool or spa temperature is easily done by simply depressing the appropriate up or down arrow until the display reads the desired
At any time, you wish to know the temperature setting of the pool or spa, simply press the appropriate up or down arrow, the display will flash once and display the