Figure 5. | Liner |
| |
| Pool Wall |
| Body |
Flow Director | |
lubricant only. Do not use | |
Flange | any petroleum lubricants. |
| Bulb Assy. |
Nut |
| Red Cap/Plug. |
(Bulb Assy.) |
| |
|
| Remove after bulb is in |
GASKET | GASKET | place in the Fitting Body. |
NOTE
For narrow, interlocking, extruded aluminum wall panels, center flange between the ridges while viewed from the inside of the pool. Add the spacer and additional gasket to the flange before inserting the flange through the wall panel. This is necessary to accommodate a fountain attachment.
WARNING
The light fixture must be mounted so that the word "top" is at the top of the fixture when installed. Incorrect orientation and a low water condition can damage the light fixture.
11.With the inlet port of the fitting body in the 3 O’clock position, place the fitting body against the threads of the flange and keeping the inlet port in the 3 O’clock position; see Figure 6. Hand tighten the flange as tight as possible. Rotate the flange, not the body.
CAUTION
Do not over tighten the flange.
12.To complete the tightening process, hold the flange in place and rotate the fitting body until the inlet port is in the 6 o’clock position; see Figure 6.
13.Take a hose clamp and place it over the return hose cuff.
14.Slip the return hose from the equipment, over the inlet port, and tighten the hose clamp securely; see Figure 7.
15.Take the bulb assembly and insert it through the flow director. Note the aligning keyway on the bulb assembly as shown in Figure 8. The keyway must point in the same direction as the top key on the fitting body.
Inlet Port
3O’clock position
6 O’clock | Figure 6. |
P/N 98748000 | 4 | REV. F |