Pentair Quasar Section, Relamping Instructions, can result in death or severe personal injury

Models: Quasar

1 12
Download 12 pages 39.15 Kb
Page 9
Image 9
SECTION V.

SECTION V.

RELAMPING INSTRUCTIONS

 

 

WARNING

 

Risk of electric shock. Disconnect power before servicing this unit. Failure to disconnect power

 

can result in death or severe personal injury.

1.

It is desirable to reduce the water level to the lower edge of the flow director. This makes bulb

 

assembly replacement easier, but it is not mandatory.

2.Remove power from the unit by taking the power cord’s 3-prong plug and disconnecting it from its electrical outlet, or in the case of a hard-wired application, by turning the respective circuit breaker to the OFF position.

3.

Remove the snap-on cord cap by inserting a slotted

 

screw driver into the access hole as illustrated in

 

Figure 20 and prying upwards.

4.

Disconnect both wire connectors and put the snap-on

 

cord cap aside in a dry location and remove the bulb

 

assembly nut.

5.

At this point you should have the new replacement

 

bulb assembly accessible and confirm that the red

 

cap/plug is pressed firmly into the bulb assembly to

 

prevent water from entering the bulb assembly.

6.

If you were able to lower the water level as suggested

 

in step 1, then simply remove the old bulb assembly

 

by pulling on the flow director while pushing the bulb

 

assembly from the outside of the pool. If you were

 

unable to lower the water level, follow these

 

instructions: push the bulb assembly out from the

Sheet Metal Screw RELAMPING INSTRUCTIONS

Side of

Pool

Support

Pool Wall

Cable Clamp to hold wire tight against the wall.

Figure 18.

outside of the pool, keeping the back of the fitting

covered with a folded rag in the palm of your hand to

prevent water loss from the rear of the fitting body; see

Figure 4. Pull the flow director and bulb.

7. Take the new replacement bulb assembly with the red

cap/plug in place and insert the bulb assembly

through the flow director. Note the aligning keyway

on the bulb assembly as shown in Figure 8. The

keyway must point in the same direction as the top

key on the fitting body.

Now, from inside the pool, push the bulb assembly

with the flow director into the fitting body until both

are nearly flush against the inside pool wall. You can

now remove your hand and the fitting should again be

sealed.

Pool

Pool Wall

Figure 19.

Figure 20.

REV. F 1-6-05

9

P/N 98748000

Page 9
Image 9
Pentair Quasar owner manual Section, Relamping Instructions, can result in death or severe personal injury, Pool Wall