16.Now, from inside the pool, push the bulb assembly and flow director with the red cap/plug in place into the fitting body until the bulb assembly/flow director are nearly flush against the inside pool wall.
17.Thread the bulb assembly nut until it just touches the fitting body, then finger tighten.
CAUTION
Do not over tighten as adjustability of the flow director may be impaired and/or damage to parts causing leakage may occur. If the flow director does not rotate by hand, the nut is too tight.
18.Take the red cap/plug off and gently bring the wire connectors through the back side of the bulb assembly. Save the red cap/plug for storage and winterizing.
CAUTION
This lighting fixture may be damaged if subjected to freezing weather. See winterizing instructions for details on how to store the bulb assembly.
SECTION III. ELECTRICAL CONNECTIONS FOR STORABLE POOLS
1.Connect the wire connectors from the bulb assembly to the wire connectors attached to the
NOTE
There is no polarity (no positive or negative) to the wires, either connection will work.
2.Snap the cap onto the end of the body and turn so that the electrical cord is pointing down.
| Liner |
| Pool Wall |
Body | Wall |
| Flange |
Clamp
Gaskets (2)
Figure 7. Hose
3.Mount the transformer on the vertical wall using the single screw provided.
4.Plug the power cord’s
5.If the light is not on, press the switch on the transformer case once.
WARNING
Risk of electric shock. Connect only to a
Key
Keyway
Figure 8.
REV. F | 5 | P/N 98748000 |