Installation

The module comes equipped with a bank of DIP switches and jumpers for setting configuration.

The default dip switch settings (all switches in the UP position) and default jumper settings will work for most installations.

The following steps are used to configure the Perle 10/100 Ethernet Media Converter Module:

1.Set the Auto-MDIX jumper (optional).

2.Set the Auto-Config jumper (CM-110 only) (optional)

3.Set the DIP switch settings (optional).

4.Insert the Media Converter Module into the Chassis.

5.Connect the fiber cable.

6.Connect the copper cable.

Auto-MDIX Jumper

Note: The factory settings for Auto-MDIX will work for most installations, but if there is a need to modify the settings, follow the procedure below.

The AUTO-MDIX jumper (J5) is located on the upper edge, at the midpoint of the module (see diagram below for labelling).. By covering or strapping pins 2 and 3(AUTO), the C-110 and CM-110 will automatically detect the Ethernet cable’s polarity and configure itself as either an MDI or an MDIX device. By covering or strapping pins 1 and 2(MDIX), the C-110 and CM-110 will operate as an MDIX device Removing the strapping is the same as AUTO.

NOTE: The default jumper setting is AUTO

Perle 10/100 Media Converter Module – Installation Guide 3

Page 3
Image 3
Perle Systems CM-110-XXXXX, C-110-XXXXX manual Installation, Auto-MDIX Jumper