Event Logs
29
Alarm logs:
* Bad internal block checksum detected
Generated when power up diagnostics finds a fault in the internal block of the EEPROM.
* Closing remote site X (call limit)
Generated when the specified number of calls has been exceeded.
* Closing remote site X (callback failure)
Generated when the remote site interpreted the call sequence as a callback. However, a callback was not
completed in the expected time frame.
* Closing remote site X (force disconnect)
Generated when the connection to a remote site is being c losed due to a force disconnect.
* Closing remote site X (inactiv ity)
Generated when the connection to a remote site is being closed due to an inactivity timeout .
* Closing remote site X (IP triggere d RIP)
Generated when the connection to a remote site is being c losed due to failure of IP triggered R IP.
* Closing remote site X (last ses sion)
Generated due to the termination of th e last session.
* Closing remote site X (link disabled)
Generated due to the link being dis abled by the operator.
* Closing remote site X (no NCPs open)
Generated when no Network Control Protocols oper ating.
* Closing remote site X (nonexista nt)
Generated when remote site being dele ted by the operator.
* Closing remote site X (not enabled)
Generated when remote site autocall bei ng disabled by the operator.
* Closing remote site X (resumption f ailure)
Generated due to failure to resume a su spended connection.
* Closing remote site X (schedul ed down)
Generated due to time-of-day schedule deactivation of the connection.
* Closing remote site X (suspe nsion timeout)
Generated due to reaching maximum time that the connecti on may be suspended.