Filtering

 

 

5

From the MAC ADDRESS FILTERS MENU, enter a 1.

 

This will place you at the first EDIT MAC ADDRESS FILTER MENU screen.

 

At the prompt enter the MAC address for which you want to specify the filter.

6

Enter the 12-digit Ethernet address of the host system in the following format: 000001020304 (enter a

 

Return)

The edit screen will fill in the information that the table knows about this address. For this example, let us assume that it knows that the address is “present” and located on the LAN of the partner bridge/router.

7Enter a 4 to Enable the “Forward if Destination” parameter. The edit screen will be updated to show the new information.

At this point, the address is added to the permanent filter table of the local LAN. This entry, therefore, will not be subject to the aging timer, and will remain active until it is removed from the permanent entry table.

When a frame of information is seen on the local LAN that contains the address of the host system in the destination field of the frame, the bridge/router will forward it. All other frames seen on the local LAN that are destined for the remote LAN will be filtered.

Security—“Forward if Source”

Forward if Source is a function that allows you to forward an Ethernet frame if the source address of the frame equals the address that the Forward if Source function has been applied to.

Example:

Assume that a Personal Computer is located on segment 1 on the local bridge/router. This station belongs to the head of Marketing. This station requires access to all the services that exist on the remote LAN but no other station on the local LAN is allowed to access the remote LAN. This can be easily accomplished with a “Forward if Source.”

The Ethernet Address for this Personal Computer is: 01-02-03-04-05-06

Again, this address uniquely identifies this computer station.

To configure the bridge/router to ensure that only this station is able to access facilities on a remote LAN segment, follow the instructions below:

1From the MAIN MENU of the console of the local bridge/router, enter a 1. (Enter an “=“ from any menu to go back to the MAIN MENU.)

This will place you at the CONFIGURATION MENU, where access to the filtering menu is obtained.

2From the CONFIGURATION MENU, enter an 8.

This will place you at the FILTER SET-UP MENU, where access to the individual filtering menus is obtained.

3From the FILTER SET-UP MENU, enter a 1.

This will place you at the MAC ADDRESS FILTERS MENU, where access to the MAC Address filters is obtained.

45

Page 45
Image 45
Perle Systems P840 manual Filtering, Security-Forward if Source

P840 specifications

Perle Systems is renowned for its high-performance networking hardware, and the Perle P840 model exemplifies this reputation with its advanced features and technologies. Designed for small to medium-sized enterprises, the P840 serves as a versatile and reliable solution for connectivity needs.

One of the main features of the Perle P840 is its robust network performance, supporting both Ethernet and serial connectivity. With support for RS-232, RS-422, and RS-485 interfaces, the P840 enables seamless integration of legacy devices into modern network architectures, allowing businesses to leverage existing infrastructure without the need for extensive upgrades.

The P840 also boasts advanced security features to protect sensitive data during transmission. It supports SSL encryption and VPN capabilities, ensuring that data travels securely across the network. Additionally, it implements strong authentication protocols, providing organizations with peace of mind knowing that their communications are safeguarded against potential threats.

Another standout characteristic of the P840 is its flexibility in configuration. It offers multiple port configurations, allowing for customization based on specific user needs. With options for both managed and unmanaged modes, the device can easily adapt to various network environments. This flexibility makes it suitable for diverse applications, including industrial automation, process control, and telecommunications.

The Perle P840 is designed for durability and reliability, featuring a rugged enclosure that can withstand demanding environments. Its solid-state components reduce the risk of failure, contributing to increased uptime and lower maintenance costs. Furthermore, the compact design allows for easy installation in tight spaces, making it a practical choice for various deployment scenarios.

In terms of management and monitoring, the P840 includes an intuitive web-based interface, enabling administrators to configure settings and monitor network performance effortlessly. SNMP support further enhances management capabilities, allowing for integration into larger network management systems.

Overall, the Perle P840 stands out as a powerful solution for enterprises seeking seamless connectivity, robust security, and flexibility in configuration. Its combination of advanced features and durable design makes it an ideal choice for industries requiring reliable serial and network connectivity in challenging environments. With the P840, businesses can build a resilient networking infrastructure that supports their growing demands while safeguarding their critical data.