INSTALLATION OF FAN COIL:

The extended liquid and suction pipes and drain hose are hidden inside a slot at the back of the fan coil. This allows the hole on the wall to be either on the right or left side of the fan coil.

RIGHT SIDE HOLE POSITION: The piping and drain hose are routed straight through the hole.

LEFT SIDE HOLE POSITION: The piping and drain hose run from the right side to the left side of the unit, hidden in the slot at the back of the unit before routing through the hole on the left side of the unit.

MOUNTING FAN COIL UNIT: Hook the fan coil onto the upper portion of the installation plate ensuring that it sits securely on the installation plate.

Press the lower portion of the unit against the installation plate until the hooks at the back of the unit are securely engaged with the installation plate.

MOUNTING CONDENSING UNIT:

 

Do not place the condensing unit

 

directly on the ground. It should

 

preferably be placed on a slightly

 

raised platform to prevent rain water

 

from splashing into it. Also ensure

 

that it is level. Avoid installing the unit

 

in places where flammable gases

 

may be present.

beams or blocks

 

If necessary, due to the placement conditions,

 

rubber cushions can be placed underneath the

 

outdoor unit.

Page 6
Image 6
Philips AMW, AMC 60, AMC 45, AMC Series, AMC 30, AMC 25 Installation of FAN Coil, Mounting Condensing Unit