BDL4680VL

Cooling Fan

Select {On} to turn on the cooling fan all the time. Select {Auto} to turn on/off the cooling fan according to the display’s temperature.

NOTES:

The default {Auto} option will start running the cooling fan if the temperature of 60°C (140°F) is reached.

A temperature-warning message will be shown on the screen if the temperature reaches 70°C (158°F).

After the temperature reaches 70°C (158°F) for three successive ininutes and a temperature-waning message shown on the screen for

10 seconds, the display power will be shut down automatically while Power LED will be blinking red & green.

Factory settings

Reset all your customized settings to the factory defaults.

5.3.Network Settings

1.Press [] HOME button, and go to Setup menu.

2.Choose Network Settings and press [] button.

View network settings

Network settings

Static IP configuration

Digital Media Renderer - D...

Network name

Clear Internet memory

View network settings

View connected network status.

Network settings

{Network configuration}: Choose how this display should assign addresses to the network resources.

The user can choose {DHCP & Auto IP} (suggested) or {Static IP}.

Static IP Configuration

Define {IP address}, {Netmask}, {Gateway}, {DNS1}, and {DNS2} for this display. If {Network settings} {Static IP} is chosen.

Digital Media Renderer - DMR

Receive multimedia files from the connected device by your network.

Network name

In the multiple-display connection, you can rename each display for easy identification.

Use the on-screen keyboard or the remote control keypad to enter the name.

Clear Internet memory

Clear all the cookies, bookmarks, history list and text used for auto fill.