Philips Semiconductors Product specification
TOPFET high side switch BUK216-50YT SMD version

UNDERVOLTAGE & OVERVOLTAGE CHARACTERISTICS

Limits are at -40˚C Tmb 150˚C and typicals at Tmb = 25 ˚C. Refer to TRUTH TABLE.
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Undervoltage
VBG(UV) Low supply threshold voltage12 4.2 5.5 V
VBG(UV) Hysteresis - 0.5 - V
Overvoltage
VBG(OV) High supply threshold voltage235 45 50 V
VBG(OV) Hysteresis - 1 - V

TRUTH TABLE

ABNORMAL CONDITIONS
DETECTED LOAD
INPUT SUPPLY LOAD OUTPUT STATUS DESCRIPTION
UV OV LC SC OT
L X X X X X OFF H off
H 0 0 X 0 0 ON H on & normal (LC not detected!)
H 1 0 X X X OFF H supply undervoltage lockout
H 0 1 X 0 0 OFF H supply overvoltage shutdown
H 0 0 0 1 0 ON L SC detected (without trip)
H 0 0 X X 1 OFF L OT shutdown

KEY TO ABBREVIATIONS

L logic low UV undervoltage
H logic high OV overvoltage
X don’t care LC low current or open circuit load
0 condition not present SC short circuit
1 condition present OT overtemperature
1 Undervoltage sensor causes the device to switch off and reset.
2 Overvoltage sensor causes the device to switch off to protect its load.
March 2002 5 Rev 1.200