Circuit Descriptions and Abbreviation List
EN 30 FHP PDP9.
9. Circuit Descriptions and Abbreviation List
9.1 Board Function Description
9.1.1 Logic Board Function
Data Processor
Gamma adjustment (1 / 2.2 / 2.4 / 2.6 / 2.8).
NTSC/EBU format (Colour matrix) Switch.
RGB gain Control (White balance adjustment, amplitude
limitation).
Error diffusion technology (grey scale adjustment).
Dither (grey scale adjustment).
Burn-in pattern generation.
Data Converter
Quasi out-line adjustment (luminous pattern control).
Scan Controller
Address driver control signal generator (ADM).
Scan driver control signal generator (SDM).
X/Y sustain control signal generator.
Waveform ROM
Waveform pattern for drive / timing memory.
MPU
Synchronous detection.
System control.
Driving voltage (Va, Vs, Vr, Vw) adjustment.
Abnormal watch (breakdown detection) / abnormal
processing.
I_s (sustain) current control (sustain pulse control).
I_a (address) current control (sub-field control).
External communication control.
Flash memory (firmware).
EEPROM
Control parameter memory.
Counts operating time (number of hours).
Abnormal status memory (16 places).
9.1.2 Function of X-SUS Board
DC/DC power supply block
Vcc (+5V) -> Ve (+17V) / XFve (+18V, floating).
X Switching Block
Switching during address period.
Switching during sustain period.
Switching during reset period.
Current Detector Block
I_sx (sustain) current detection.
I_ax (address) current detection.
9.1.3 Function of Y-SUS Board
DC/DC Power Supply Block
Vcc (+5V) -> Ve (+17V) / YFve (+ 18V, floating)
Vs (+85V) -> Vw (+185V)
Switching Block
Switching during address period.
Switching during sustain period.
Switching during reset period.
Current Detector Block
I_sy (sustain) current detection.
I_sp (SDM) current detection.
9.1.4 Function of ADM Board
Address Driver Module
Supplies voltage Va to the glass plate.
9.1.5 Function of SDM Board
Scan Driver Module
Supplies voltage Vs to the glass plate.
9.1.6 Function of PSU Board
Stand-by Power Supply Block
AC100-240: +5V & +3V3 Stand-by.
PFC Block (AD/DC Power Supply Block)
AC100-240: +390V.
AD/DC Power Supply Block
+380V, Vcc (+5V), Vs (+80V), Va (+60V).
Current Detection Block
l_a (address) current detection.
Abnormal Voltage Monitoring
Vs excess voltage monitoring.
Va excess voltage monitoring.