Service Modes, Error Codes, and Fault Finding
EN 12 FHP PDP5.
5.4 Repair Instructions
5.4.1 General
In case of:
a broken glass panel,
a defective flex foil, or
a defective Y-COM IC on the flex foil
the PDPs need to be send back via the central repair procedure
of EuroService.
In other cases the Plasma Display Panels must be repaired on
board level.
5.4.2 42” A4 ALiS Plasma Display Panel
The involved Plasma Display Panel is:
The available modules for these Plasma Display Panels are:
Remark:
1. If the LOGIC board is defective, the procedure mentioned
in figures "Logic Board Exchange (1 and 2)" must be used.
Display type Service code number
FPF42C128135UA-52 9322 235 43682
Module description FHP code number Service code number
X-SUS board FPF33R-XSS0041 9965 000 35647
Y-SUS board FPF33R-YSS0042 9965 000 35648
Logic board FPF33R-LGC0061 9965 000 35646
A-BUS Left FPF33R-ABL0038 9965 000 35649
A-BUS Right FPF33R-ABR0039 9965 000 35650
X-BUS board FPF33R-XBU0035 9965 000 35651
Signal Cable LOGIC-X-SUS FPF29R-CBL001411 9965 000 32669
Signal Cable LOGIC-Y-SUS FPF29R-CBL001412 9965 000 32670
Signal Cable LOGIC-ABUS-L FPF29R-CBL001401 9965 000 32668
Signal Cable LOGIC-ABUS-R FPF29R-CBL001421 9965 000 32671
Power Cable X-SUS-Y-SUS FPF29R-CBL003601 9965 000 32672
Power Cable X-SUS-ABUS-R FPF29R-CBL003701 9965 000 32673