Philips iQ24 To load the Avent Tempo Natural Feeding Nurser, Dishwasher Basket see diagram F

Models: iQ24

1 11
Download 11 pages 53.26 Kb
Page 5
Image 5
(see diagram E)

US

the pump body/bodies into the slot/s in the upper basket. Arrange other breast pump components as shown.

2.Place remaining components of the pump in the lower basket.

3.Up to six 4 oz / 125 ml or 9 oz / 260 ml bottles

(not including screw rings, nipples or dome caps) can be sterilized with the pump.

4.Follow sterilizing instructions.

To load the AVENT Tempo Natural Feeding Nurser

Before each use, wash items to be sterilized in mild, soapy water, and rinse.

1.Open the inner locking ring of the screw ring and place the screw ring in the basket with the locking tab facing downwards. Ensure that the parts of the screw ring that are in contact with the nipple are facing upwards.

2.Place the nipple and the dome cap in the basket as you would when sterilizing a bottle assembly.

3.Follow sterilizing instructions.

To remove sterilized items during or after a cycle

1.Let the sterilizer cool down for 3 minutes after sterilizing cycle has been completed.

2.Press the control button to reset (Mode 1) or pause (Mode 2) the unit.

3.Wash your hands thoroughly before removing the sterilized items.

4.Remove the lid.

5.If necessary, shake excess water from items before assembling.

6.The tongs can be used to remove small items and to pull the sterile nipples through the screw rings of the bottles.

7.Removed items must be used/assembled immediately or re-sterilized. Expressed milk can be stored in a sterile breast milk container in the refrigerator for up to 48 hours (not in the door), in the freezer for up to 3 months, or in a zero-degree freezer for up to 6 months. Infant formula should be made up fresh for each feed.

8.In Mode 1, the sterilizer must be left to cool for at least 10 minutes between each use.

9.In Mode 2 – items can be removed/replaced and then the cycle restarted. To restart, press the control button. The unit will immediately enter a new sterilization phase and continue the 24 hour cycle from where it was interrupted. If unplugged the countdown cycle will stop.

Dishwasher Basket (see diagram F)

1.Two baskets can be clipped together to hold small items such as nipples, breast pump parts etc. for washing in the top rack of your dishwasher prior to sterilization.

2.To clip together, align the baskets so that the indicators are opposite each other and snap the baskets together. To open, pull apart

with fingers.

Warning: Your Philps AVENT items may discolor over time if they are washed in the dishwasher with dirty items covered with remnants of strong sauces, such as tomato sauce.

Care of your sterilizer

Using distilled water in your iQ24 Sterilizer can reduce limescale build up. You should de-scale your sterilizer every four weeks, or as often as needed in hard water areas, to ensure it continues to work 100% effectively.

Pour 100 ml vinegar mixed with 200 ml cold water into the sterilizer. Allow to stand in the unit until any limescale has dissolved. Drain and rinse the inside of the sterilizer thoroughly. Wipe dry.

Limited Guarantee

Philips AVENT guarantees that the iQ24 Sterilizer be free from manufacturers defects for 12 months from the date of purchase. In the event of a defect, Philips AVENT will repair or replace such parts free of charge with proof of purchase. The iQ24 Sterilizer must be used according to the instructions. The claim must not be a result of a accident, misuse, dirt, neglect or normal wear and tear. For questions about this product or our guarantee please call Customer Service at 1.800.54.AVENT.

Philips AVENT is here to help

For our complete catalog of mother and baby care products and breastfeeding information Call TOLL-FREE 1.800.54.AVENT

MANUFACTURED FOR: PHILIPS DOMESTIC APPLIANCES AND PERSONAL CARE COMPANY, A DIVISION OF PHILIPS ELECTRONICS NORTH AMERICA CORPORATION. 1600 SUMMER STREET, 5 FL. STAMFORD, CT 06905-9991. www.philips.com/AVENT

US

Electronic Display Guide

Sterilizer plugged in and ready for mode selection

BEEP

BEEP

Ready for Mode 1 selection

Ready for Mode 2 selection

BEEP

BEEP

Mode 1 sterilization in progress – indicated

Mode 2 sterilization in progress – indicated by a

by a beep and rotating ‘0’

beep and three ascending and descending bars

Numerical countdown indicates sterilization almost complete*

BEEP

X 5

Sterilization complete – indicated by 5 beeps and three flashing bars

– items will remain sterile for up to 6 hours provided the lid is not opened

Up to 6 hours sterile

Up to 4 hours sterile

Up to 2 hours sterile

time remaining

time remaining

time remaining

 

 

 

BEEP

Mode 1 cycle (6 hours)

Completion of Mode 2 cycle (24 hours) – indicated by a long beep and a flashing ‘0’

BEEP

Water level too high. See ‘Troubleshooting’ on back cover

BEEP

Water level too low. See ‘Troubleshooting’ on back cover

6

* Mode 1 only

7

Page 5
Image 5
Philips iQ24 To load the Avent Tempo Natural Feeding Nurser, Dishwasher Basket see diagram F, Care of your sterilizer

iQ24 specifications

The Philips iQ24 is an innovative healthcare solution designed to enhance patient comfort and diagnostics in modern medical environments. This advanced device integrates cutting-edge technology with user-friendly features, making it a vital tool for healthcare professionals.

One of the main highlights of the iQ24 is its high-definition imaging capability. This device utilizes advanced imaging technologies that provide clear, detailed visuals, allowing for accurate diagnosis at the first point of care. With enhanced resolution and contrast, clinicians can quickly identify conditions, leading to faster treatment decisions.

The iQ24 incorporates various imaging modalities, including ultrasound and digital radiography. These technologies ensure that healthcare providers have access to a comprehensive diagnostic toolkit, streamlining the process of patient assessment while minimizing the need for multiple devices. The flexibility of the iQ24 means that it can be adapted for various medical applications, from obstetrics to musculoskeletal imaging.

One notable feature is its intuitive user interface, designed to facilitate ease of use even for those less experienced with imaging technology. The touchscreen controls and customizable settings enable clinicians to focus more on patient care rather than navigating complex menus. This user-centric design improves workflow efficiency and enhances the overall healthcare experience.

Another significant characteristic of the Philips iQ24 is its portability. Lightweight and compact, it is engineered for use in various clinical settings, from emergency rooms to outpatient facilities. This versatility ensures that high-quality imaging is accessible whenever needed, thereby improving patient outcomes.

Additionally, the iQ24 emphasizes patient safety and comfort. With its low radiation exposure during imaging, it aligns with modern standards for minimizing health risks associated with diagnostic procedures. The device also features ergonomic design elements that improve patient comfort during examinations.

Overall, the Philips iQ24 represents a significant leap forward in medical imaging technology. Its combination of high-definition imaging, user-friendly interface, portability, and patient safety features make it an essential instrument in modern healthcare delivery. As the demands of healthcare continue to evolve, devices like the iQ24 will play a crucial role in meeting those needs while providing exceptional patient care.