Philips P-5794-B warranty Ordering, Electrical andTechnical Data, 95% Lumen Maintenance

Models: P-5794-B

1 2
Download 2 pages 47.01 Kb
Page 2
Image 2

PhilipsT8 32W Extra Long Life Lamps featuring ALTO IITechnology

Ordering, Electrical andTechnical Data

 

 

 

 

 

Color

Nom.

Rated Average Life (hrs)1

Approx.

 

 

 

 

Product

Ordering

 

Pack.

Temp.

Length

12-hr on

12-hr on

Initial

Design

 

Lumen

 

Number

Code

Watts

Qty.

(Kelvin)

(In.)

Ins. Start

Prog. Start

Lumens2

Lumens3

CRI

Maint.

E

15202-5

F32T8/TL830/XLL/ALTO

32

25

3000

48

40,000

46,000

2950

2800

85

95%

E

15203-3

F32T8/TL835/XLL/ALTO

32

25

3500

48

40,000

46,000

2950

2800

85

95%

E

15204-1

F32T8/TL841/XLL/ALTO

32

25

4100

48

40,000

46,000

2950

2800

85

95%

E

15205-8

F32T8/TL850/XLL/ALTO

32

25

5000

48

40,000

46,000

2850

2700

85

95%

1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.

2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions.For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the designated lamp lumen output.

3) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.

E Lamp meets US Federal Minimum Efficiency Standards.

This lamp is better for the environment because of its reduced mercury content. All Philips ALTOIIlamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and local regulations.

95% Lumen Maintenance

Philips T8 32W XLL Lamps

100%

 

98%

(%)

 

Output

96%

 

Light

94%

 

92%

 

90%

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

40,000

45,000

50,000

Lamp Operating Hours

Rated Average Life

Philips T8 32W XLL Lamps

Instant Start Ballast

Programmed Start Ballast

BASED ON 3 HOURS PER START4

36,000

40,000

BASED ON 12 HOURS PER START1

40,000

46,000

0

10,000

20,000

30,000

40,000

50,000

Rated Average Life in Hours

4)Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.

Footnotes from front page:

* When compared to an industry standard 4' T8 32W lamp with 24,000 hours rated average life (12 hours per start on an instant start ballast), with 2800 lumens and 75 CRI.

Specifications are subject to change without notice. © 2007 Philips Lighting Company. All rights reserved. Printed in USA 06/07

P-5794-B

www. philips.com

Philips Lighting Company

Philips Lighting

200 Franklin Square Drive

281 Hillmount Road

P.O. Box 6800

Markham, Ontario

Somerset, NJ 08875-6800

Canada L6C 2S3

1-800-555-0050

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification. Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.

Page 2
Image 2
Philips P-5794-B warranty Ordering, Electrical andTechnical Data, 95% Lumen Maintenance, Rated Average Life