![PowerLight Models 1250DR and 2500DR](/images/new-backgrounds/159367/15936715x1.webp)
PowerLight Models 1250DR and 2500DR
tm
1 | 1 |
2 | 10 |
tm
Flash Power:
Use the Adjust button to turn on the Flash ws red LED. Adjust the PowerLight 1250DR or 2500DR Flash power setting using the 1/2 or 1/10
Ready Light:
The PowerLight 2500DR is fully charged when the READY lamp is on. Lowest power (32ws) charge time is a maximum of .8 seconds and at full power charge (1000 ws) time is a maximum of 3 seconds. The unit may be flashed before fully charged.
The PowerLight 1250DR is fully charged when the READY lamp is on. Lowest power (16ws) charge time is a maximum of .5 seconds and at full power charge (500 ws) time is a maximum of 1.5 seconds. The unit may be flashed before fully charged.
Modeling Light:
The modeling light has three modes of operation:
1.MANUAL [press the ADJUST button to turn the MODEL yellow LED on] adjusts the modeling lamp intensity using the 1/2 or 1/10
2.TRACK mode causes the modeling lamp intensity to track the FLASH setting. The modeling lamp may be set to full intensity at any FLASH value, by simply pressing the TRACK/SET button a second time, with the FLASH already set to desired watt- seconds. Setting is retained when user returns from another mode.
3.FULL ON/OFF is exactly what it says. Press the FULL ON/OFF button to turn the modeling lamp OFF (LED off) or ON (LED on).