OPERATIONAL PARAMETERS
Solair! Radio-Sync, Constant-Color PLR500DR
Voltage Smart# Radio-Sync, Constant Color PLRX500DR
Flashing Rate:
The unit recharges quickly, as indicated by the READY light on the control panel. A
quick series of flashes can be obtained within the limits of the recharge time. Continuous
rapid flashing, however, can overheat and damage the flashtube and internal parts. The
maximum recommended rate of flashing would depend upon the power level being used
and the amount of operation time. Use the following chart to serve as a guide for the
maximum rate to use in your situation.
Power Level
Operating
Sec. Between
Number of
Time
Flashes.
Flashes
Full
Continuous
8.3
Continuous
11 Minutes
6
116
4 Minutes
4
60
1/2
Continuous
4
Continuous
4 Minutes
2
124
1.4 Minutes
1
85
1/4
Continuous
2
Continuous
Exposure Information:
The following charts give the BCPS output for various umbrellas and reflectors.
Coverage angle is given in degrees.
Umbrella
32 inch
45 inch
60 inch
Coverage
120 degree
120 degree
120 degree
Full Power
5500
5583
5583
_
2750
2792
2792
_
1375
1396
1396
1/8
688
698
698
1/16
344
349
349
1/32
172
174
174
1/64
86
87
87
1/128
43
44
44
Reflector
PL14R
PL16R
PL18RWD
PL24R
Diameter
14”
16”
18”
24”
Coverage
40°
60°
126°
145°
Full Power
17500
23333
3570
4200
_
8750
11667
1785
2100
_
4375
5833
892
1050
1/8
2188
2916
446
525
1/16
1094
1458
223
262
1/32
547
729
112
131
1/64
274
365
56
66
1/128
137
182
28
33
GN@ASA100/10’
305
350
137
150