55 
• Pressing the PTT button when scan is ON will cause the radio to transmit on the displayed 
channel or to the currently selected channel depending on programming. 
• Pressing < when scan is ON will cause the radio to recall the scanned channel that was last 
received. This channel is recalled for a period equal to the scan hang time. 
13.6  TURNING SCAN OFF Toggle the scan operation OFF by pressing k. The radio will resume operation on the selected 
channel. 
13.7 SQUELCH ADJUST In the conventional mode of operation, the squelch can be re-adjusted in the MENU selection mode or 
from a front panel key on the keypad that has been pre-programmed using ProGrammer™ software. A 
default value of 9, or any user level between 1 and 16, can be selected using ProGrammer software. The 
user can change this setting either of two ways from the front panel keys. 
A value of 16 requires a strong signal to open squelch, a value of 2 requires a very weak 
signal to open squelch, and a value of 1 is open squelch. 
When the squelch adjust feature is activated, Channel Guard, T99 decode, and Scan are 
disabled. When the squelch adjust feature is exited, Channel Guard, T99 decode, and Scan 
are restored to their previous states. 
13.7.1 Menu Selection
1.   Press the  m key and then use the RAMP control , or . to scroll through the 
selections until SQUELCH is displayed. Then press m (select) again. 
2.   The display will show SQLCH=xx, where "xx" is the value between 1 and 16. 
3.   Use the RAMP control , or . to scroll through the values. Then press the m (select) 
key to save the new value after the display time-out (2 seconds). The displayed value will be 
selected and saved. 
4.   If the m or c key is pressed before the time-out, the menu feature will exit and the 
squelch level will not be updated. The original value will be restored. 
13.7.2 Pre-Programmed Keypad Key
1.   Press the pre-programmed key and the display will indicate SQLCH=xx, where "xx" is the 
value between 1 and 16. 
2.   Use the RAMP control , or . to scroll through the values. Then press the m (select) 
key to save the new value or wait for the display time-out (2 seconds). The displayed value 
will be selected and saved.