FL Descriptionof Error Causes if with a DVD Causes if with a CD Operation of the
39 SGC converge
timeout SGC could not converge during detects the peak Open
41 Spindle timeout The unit did not enter Stop mode within 10 seconds of issuance of a Stop command. Stop
48 Spindle FG
transition timeout
The spindle could not converge into within ± 12% of
the target FG rotation speed within 10 seconds after
spindle kick. The first time after startup (the first time
after disc distinction), it doesn't become the number of
the target rotation within five seconds. The first time
after startup, detects the abnormal rotation number of
high-speed continuously 3 loops. DVD: 5 to 9 mS ,
CD: 40 to 60 mS
Stops. (FG timeout)
49 Spindle PLL
transition timeout
After the second times after startup, it doesn't become the number of the target rotation
within five seconds. Detects the abnormal high-speed or low-speed rotations.DVD: 5 to
9 mS , CD: 40 to 60 mS
Stops.
("73" is displayed during
starting process.)
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB. Stops.
("73" is displayed during
starting process.)
51 Auto sequence
timeout of peak ABUSY did not return within 1 second after the
DDTCT (peak detection) command was sent. Stop
52 Auto sequence
timeout of focus
jump down
ABUSY did not return within 30 mS after the FJMPD
(Focus jump 1 to 0) command was sent. Stop
53 Auto sequence
timeout of focus ABUSY did not return within 30 mS after the FJMPU
(Focus jump 0 to 1) command was sent. Stop
54 Auto sequence
timeout of play AGC ABUSY did not return within 50 mS after the GSUMON
(play-AGC-measuring) command was sent. Stop
55 Auto sequence
timeout of disc-type-
sensing
ABUSY did not return within 2 seconds after the
DJSRT (disc-sensing) command was sent. Stop
56 Auto sequence
timeout of ATB2
ABUSY did not return within 1 second after the
TBLOFS (Internal ATB after the completion of external
ATB) command was sent. Stop
57 Auto sequence
timeout of tracking
servo ON
ABUSY did not return within 500 mS after the TSON
(tracking servo ON) command was sent. Stop
58 Auto sequence
timeout of ATB1 ABUSY did not return within 200 mS after the TBL
(external ATB) command was sent. Stop
59 Auto sequence
timeout of focus gain
adjustment
ABUSY did not return within 2 seconds after the FGN
(focus gain adjustment) command was sent. Stop
5A Auto sequence
timeout of tracking
gain adjustment
ABUSY did not return within 2 seconds after TGN
(tracking gain adjustment) command was sent. Stop
5B Auto sequence
timeout of offset
adjustment
ABUSY did not return within 1 second after the
CMDAVE (offset adjustment) command was sent. Stop
5C Auto sequence
timeout of
modulation factor
measurement
ABUSY did not return within 200 mS after the ADJMIR
(modulation factor measurement) command was sent. Stop
5D Auto sequence
timeout of auto focus
bias
ABUSY did not return within 2 seconds after the AFB
(auto focus bias) command was sent. Stop
5F Auto sequence
already busy
A command could not be sent because ABUSY was
low. ABUSY did not return within 200 mS after TLV
command was sent. Stop
62 Pause retry error Pause mode could not be restored within three retries
after it had been released. Continues operation