Item | Description | Status |
|
|
|
3 | Fault status | On = Drive failure |
|
| Flashing = |
|
| Off = No |
|
|
|
Hot-plug SCSI hard drive LED combinations
Activity | Online LED | Fault LED | Interpretation |
LED |
|
|
|
|
|
|
|
On, off, or | On or off | Flashing | A predictive failure alert has been received for this drive. |
flashing |
|
| Replace the drive as soon as possible. |
|
|
| |
|
|
|
|
On, off, or | On | Off | The drive is online and is configured as part of an array. |
flashing |
|
| If the array is configured for fault tolerance and all other drives in the |
|
|
| |
|
|
| array are online, and a predictive failure alert is received or a drive |
|
|
| capacity upgrade is in progress, you may replace the drive online. |
On or | Flashing | Off | Do not remove the drive. Removing a drive may |
flashing |
|
| terminate the current operation and cause data loss. |
|
|
| The drive is rebuilding or undergoing capacity expansion. |
|
|
|
|
On | Off | Off | Do not remove the drive. |
|
|
| The drive is being accessed, but (1) it is not configured as part of an |
|
|
| array; (2) it is a replacement drive and rebuild has not yet started; or |
|
|
| (3) it is spinning up during the POST sequence. |
Flashing | Flashing | Flashing | Do not remove the drive. Removing a drive may cause |
|
|
| data loss in |
|
|
| One or more of the following conditions may exist: |
|
|
| • The drive is part of an array being selected by an array |
|
|
| configuration utility |
|
|
| • Drive Identification has been selected in HP SIM |
|
|
| • The drive firmware is being updated |
|
|
|
|
Off | Off | On | The drive has been placed offline due to hard disk drive failure or |
|
|
| subsystem communication failure. |
|
|
| You may need to replace the drive. |
|
|
|
|
Off | Off | Off | One or more of the following conditions may exist: |
|
|
| • The drive is not configured as part of an array |
|
|
| • The drive is configured as part of an array, but it is a |
|
|
| replacement drive that is not being accessed or being rebuilt yet |
|
|
| • The drive is configured as an online spare |
|
|
| If the drive is connected to an array controller, you may replace the |
|
|
| drive online. |
|
|
|
|
Component identification 56